Provided by the Supplier of 3 rd Party Equipmentĥ CONFIGURING THE FIELDSERVER AS A GAMEWELL FCI-E3 SERIES SERIAL CLIENTįor a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration Manual. Pigtail cable for RJ45 Port for RS-232 use Supplied by FieldServer Technologies for this driver Messages which identify the node of origin.


If there is more than one alarm panel they can be networkedĪnd configured to send event data to the primary panel. Should you require the Server side functionality to be documented and enhanced, please contact FieldServer’s sales group. The Server side of the driver is intended to support FieldServer’s Quality Assurance program and is not intended to provide complete emulation of an E3 and is thus not fully documented. The driver provides both Client and Server emulation. Node information is sent in the line preceding the event and the driver uses this to determine the panel at which the event originated and to store data appropriately. Subsidiary panels are configured to send event data to the main panel which then sends messages to the FieldServer. The driver can process messages from networked panels. The data in the FieldServer and the panel status have to be synchronized manually.

No automatic panel data synchronization technique exists. This passive Client driver does not poll for data, nor does it send data or commands to the E3, thus it cannot be used to acknowledge, silence or reset alarms and other events. Once stored in the FieldServer the data is available to be read or written using other protocols. Messages received from the E3 are analyzed and are then either discarded or used to update the FieldServer’s internal Data Arrays depending on the configuration of the FieldServer. A Gamewell FCIE3 Panel with an enabled serial port can transmit data to a FieldServer which can, in turn, make the data available to other devices including those which communicate using different protocols. The Gamewell FCI E3 Series System Control Units are manufactured by Fire Control Instruments. Driver Stats Exposed.įS-8700-132 Gamewell FCI-E3 Driver Manualġ GAMEWELL FCI-E3 SERIES SERIAL DRIVER DESCRIPTION Index value of 'Trouble' is updated to a new value of 100. Extending the Event Table.Īppendix A.1.1. Map Descriptor Example 1 – Sensor / Module Events. ĭriver Related Map Descriptor Parameters.

Ĭlient Side Map Descriptor Parameters.įieldServer Related Map Descriptor Parameters. Hardware Connections.ĭata Array Parameters.ĥ Configuring the FieldServer as a Gamewell FCI-E3 Series Serial Client.Ĭlient Side Connection Parameters. Provided by the Supplier of 3 rd Party Equipment. Supplied by FieldServer Technologies for this driver. 1 Gamewell FCI-E3 Series Serial Driver Description.